Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Front Cardiovasc Med ; 9: 842532, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35387440

RESUMEN

Objective: To evaluate the prognostic impact of the parameters of myocardial deformation using three-dimensional speckle tracking echocardiography (3DSTE) in patients with breast cancer who underwent chemotherapy with low doses of anthracyclines. Background: Chemotherapy-related cardiotoxicity has an important prognostic impact on cancer survivors. Three-dimensional STE has revealed more consistent data than two-dimensional techniques and may represent a more accurate tool in the evaluation of myocardial function in patients who underwent chemotherapy. Methods: We evaluated patients with breast cancer who were treated with anthracyclines (associated or not with trastuzumab) in five stages: baseline, after cumulative doses of 120 and 240 mg/m2 of doxorubicin, and then, after 6 months and at least 1 year after anthracyclines. Ultrasensitive troponin I (US-TnI) and a standard echocardiography study were performed at each stage. We analyzed left ventricular ejection fraction (LVEF) by Simpson's method, two-dimensional speckle tracking (2DSTE) with longitudinal and radial strain values, and 3DSTE with longitudinal, radial, and circumferential strain as well as twist, torsion, rotation, and three-dimensional global area strain (3DGAS). Cardiotoxicity was defined as a decrease in LVEF by more than 10 percentage points to a value lower than 53%. Results: We evaluated 51 female patients who were aged 50.6 ± 11 years. After the cumulative dose of 240 mg/m2 of doxorubicin, US-TnI was increased (>34 pg/ml) in 21 patients (45%, p > 0.001), LVEF remained unchanged (p = 0.178), while 2DSTE longitudinal strain was decreased (from -17.8% to -17.1%, p < 0.001) and 3DSTE detected changes in longitudinal, radial, circumferential, and area strain. After a lower cumulative dose of doxorubicin (120 mg/m2), 3DGAS (p < 0.001) was the only parameter that was changed. In the follow-up, 7 (13%) patients presented a decrease in LVEF. Three-dimensional GAS early changed to abnormal values was the only variable associated with a subsequent decrease in LVEF (definitive cardiotoxicity). Conclusion: In patients with breast cancer, 3DSTE detected early changes in area strain after very low doses of doxorubicin. The 3DGAS early changed to abnormal values was associated with a subsequent decrease in LVEF, representing a promising technique to predict chemotherapy-induced cardiomyopathy.

2.
Cardiovasc Ultrasound ; 19(1): 34, 2021 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-34688300

RESUMEN

BACKGROUND: Information is lacking concerning in-hospital echocardiography analysis of COVID-19 infection in Brazil. We evaluated echocardiographic parameters to predict a composite endpoint of mortality, pulmonary thromboembolism or acute renal failure. METHODS: A prospective full echocardiographic study of consecutive patients hospitalized with COVID-19, single tertiary centre in Brazil. We correlated echocardiographic findings to biomarkers, clinical information, thoracic tomography, and in-hospital composite endpoint of mortality, pulmonary thromboembolism or renal failure. RESULTS: One hundred eleven patients from March to October 2020, 67 ± 17 years, 65 (58.5%) men, death was observed in 21/111 (18.9%) patients, 48 (43%) required mechanical ventilation, myocardial infarction occurred in 10 (9%), pulmonary thromboembolism in 7 (6.3%) patients, haemodialysis was required for 9 (9.8%). Echocardiography was normal in 51 (46%) patients, 20 (18%) presented with decreased left ventricle ejection, 18 (16.2%) had abnormal left ventricle global longitudinal strain, 35 (31%) had diastolic dysfunction, 6 (5.4%) had an E/e'ratio > 14, 19 (17.1%) presented with right ventricle dilated/dysfunction, 31 (28%) had pericardial effusion. The echocardiographic parameters did not correlate with mortality, biomarkers, clinical events. Tricuspid velocity was related to the composite endpoint of mortality, pulmonary thromboembolism or acute renal failure (p: 00.3; value: 2.65 m/s; AUC ROC curve: 0.739; sensitivity: 73.3; specificity: 66.7; CI: 0.95, inferior: 0.613; superior: 0,866). CONCLUSIONS: Among hospitalized patients with COVID-19, echocardiography was normal in 51(46%) patients, and 20 (18%) patients presented with a decreased left ventricle ejection fraction. Tricuspid velocity was related to the composite endpoint of mortality, pulmonary thromboembolism or acute renal failure.


Asunto(s)
COVID-19 , Brasil/epidemiología , Ecocardiografía , Hospitales , Humanos , Masculino , Pronóstico , Estudios Prospectivos , SARS-CoV-2
4.
Circ Heart Fail ; 9(11)2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-28029639

RESUMEN

BACKGROUND: Sleep-disordered breathing (SDB) is common in patients with heart failure (HF), and hypoxia and hypercapnia episodes activate chemoreceptors stimulating autonomic reflex responses. We tested the hypothesis that muscle vasoconstriction and muscle sympathetic nerve activity (MSNA) in response to hypoxia and hypercapnia would be more pronounced in patients with HF and SDB than in patients with HF without SDB (NoSBD). METHODS AND RESULTS: Ninety consecutive patients with HF, New York Heart Association functional class II-III, and left ventricular ejection fraction ≤40% were screened for the study. Forty-one patients were enrolled: NoSDB (n=13, 46 [39-53] years) and SDB (n=28, 57 [54-61] years). SDB was characterized by apnea-hypopnea index ≥15 events per hour (polysomnography). Peripheral (10% O2 and 90% N2, with CO2 titrated) and central (7% CO2 and 93% O2) chemoreceptors were stimulated for 3 minutes. Forearm and calf blood flow were evaluated by venous occlusion plethysmography, MSNA by microneurography, and blood pressure by beat-to-beat noninvasive technique. Baseline forearm blood flow, forearm vascular conductance, calf blood flow, and calf vascular conductance were similar between groups. MSNA was higher in the SDB group. During hypoxia, the vascular responses (forearm blood flow, forearm vascular conductance, calf blood flow, and calf vascular conductance) were significantly lower in the SDB group compared with the NoSDB group (P<0.01 to all comparisons). Similarly, during hypercapnia, the vascular responses (forearm blood flow, forearm vascular conductance, calf blood flow, and calf vascular conductance) were significantly lower in the SDB group compared with the NoSDB group (P<0.001 to all comparisons). MSNA were higher in response to hypoxia (P=0.024) and tended to be higher to hypercapnia (P=0.066) in the SDB group. CONCLUSIONS: Patients with HF and SDB have more severe muscle vasoconstriction during hypoxia and hypercapnia than HF patients without SDB, which seems to be associated with endothelial dysfunction and, in part, increased MSNA response.


Asunto(s)
Insuficiencia Cardíaca Sistólica/fisiopatología , Hipercapnia/fisiopatología , Hipoxia/fisiopatología , Músculo Esquelético/irrigación sanguínea , Síndromes de la Apnea del Sueño/fisiopatología , Sistema Nervioso Simpático/fisiopatología , Vasoconstricción , Adulto , Estudios de Casos y Controles , Células Quimiorreceptoras/metabolismo , Prueba de Esfuerzo , Femenino , Antebrazo , Insuficiencia Cardíaca Sistólica/complicaciones , Insuficiencia Cardíaca Sistólica/metabolismo , Humanos , Hipercapnia/metabolismo , Hipoxia/metabolismo , Pierna , Masculino , Persona de Mediana Edad , Músculo Esquelético/inervación , Músculo Esquelético/metabolismo , Pletismografía , Polisomnografía , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/metabolismo , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...